Published xTool settings. Not tested by Kerfbook.

Laser test card

Set a range, preview the grid, and export its settings legend.

Preview

Updates as you edit

Settings

Ranges and fixed settings
Power / %
Speed / mm/s

Lines per cm applies to fill engraving only. Cut and score exports preserve it in the legend, but line operations do not use a fill interval.

Passes are rounded to whole numbers. Narrow ranges can repeat a value; each cell still has its own layer color. Fixed fields are your inputs, not inferred values for missing source settings.

Card size and labels

Long column labels rotate above the grid. On very small cells, the label font shrinks to keep rows apart.

Starting-range sources and limits

Import and layer settings

Import the SVG into your laser software and keep each exact RGB color on a separate layer. Use the CSV or JSON legend to assign power, speed, passes, and fill density. The SVG does not program your machine. Imported colors may be remapped; check every layer before running.

Convert text to paths in your laser software before processing. Labels and the optional gray frame are separate from test cells: disable them, or assign their settings separately. A PNG is a preview, not a layer file.

Color and settings legend
Values assigned to each test cell
CellColorPower %mm/sPassesLines/cm

Grid calculations and safety

These are generated ranges, not settings we have tested on your material.

Each axis includes both endpoints. A step is (maximum − minimum) ÷ (cell count − 1); passes round to the nearest whole number. Across columns, power or speed increases left to right. Down rows, speed, passes, or lines per cm increases top to bottom. A higher lines-per-cm value means a smaller fill interval: interval in mm = 10 ÷ lines per cm.

The bare grid width is columns × size + (columns − 1) × gap. Height uses rows instead of columns. The displayed dimensions include the outside labels, title, and margins, not just the test shapes. A score cell contains a single horizontal line centered in its square allocation.

  1. Check your material and machine manual before choosing a range. Do not process unknown or unsuitable material.
  2. Import the SVG at its original size. Map each cell color to the exported settings in your laser software, then check the preview and usable work area.
  3. Use suitable ventilation and keep the machine supervised. Start with a small sample and inspect the result before a larger job.

Your edits stay in this browser page. Export the legend with the SVG so the cell parameters travel with the card.

Source notes

Where the starting ranges come from

Dataset updated 2026-11-16

Presets use independent minimum and maximum non-null values from matching source rows. They can span different machines, powers, materials, and thicknesses. A minimum power and maximum speed need not occur in the same row. Missing settings are not filled in from another row; fixed tool inputs remain separate. These broad ranges are starting points to edit, not recommendations.

Diode cut test

Diode (blue)
Cut; category: all categories

101 matching rows. Range basis: minimum and maximum of each parameter’s available values.

Power / %
90–100 · 93 non-null values
Speed / mm/s
1–15 · 101 non-null values
Passes
1–5 · 101 non-null values
Lines / cm
No source values

Infrared metal mark

Infrared (1064 nm)
Bitmap engrave / Vector engrave / Fill engrave; category: Metal

13 matching rows. Range basis: minimum and maximum of each parameter’s available values.

Power / %
50–100 · 13 non-null values
Speed / mm/s
3–650 · 8 non-null values
Passes
1–1 · 13 non-null values
Lines / cm
200–220 · 8 non-null values